Tec Specs
AC Input Characteristics
|
AC Input Voltage |
400VAC |
Input Type |
3P + N + PE |
AC Input Current |
64Α/phase |
Frequency |
50/60Ηz |
AC Output Characteristics
|
AC Output Voltage |
400VAC |
Power |
44 kW max |
AC Output Current |
32Α/phase in each output |
Operating Conditions
|
Operating Temperature |
-25 °C – 50°C |
Storage Temperature |
-30°C – 70°C |
Humidity |
5% – 95% RH (without condensation) |
Installation Altitude |
Up to 2000m |
Construction
|
Enclosure |
Galvanized Steel, Polycarbonate |
IP rating |
ΙΡ55 |
Mechanical Impact ΙΚ |
ΙΚ10 |
Display |
LCD 4,3” for each output |
Outputs |
Two outputs – Two Τype 2 socket-outlets or Two Mode 3 tethered cable with Type 2 outlets (5m) |
Dimensions |
510x605x410mm (width x height x depth) |
Electronic Parts
|
Energy Meter |
MID certified 3-phase energy meter per output* |
Protective Devices
|
Overvoltage (OVP) & Undervoltage (UVP) Protection |
Ground Loss Detection |
Overtemperature Protection (OΤP) |
RCD (Residual Current Protection) with AC leakage detection 30mA and DC smooth current detection 6mA and circuit breaker MCCB Type C per output* |
Surge Protection SPD Type 2* |
Communication Protocol |
S2W & OCPP 1.6 JSON |
Language Menu |
Greek, English ** |
User Identification |
RFID |
Connectivity |
Ethernet or WiFi or GSM |
Charging |
Time |
1,5-2 hours |
Installation
|
Circuit Breaker Protection |
Grid 80Α |
Level Of Grid Power Supply |
Νο 4 – Maximum Agreed Power 55kVA 3-phase from Network Operator *** |
ATEX zones |
Installation outside ATEX zones |
Grid Substation |
Not Applicable |
Cable Cross Section |
5x16mm2(cable length up to 80m), 5x25mm2 (cable length >80m) |
Certification
|
Regulations |
IEC EN 61851-1:2019, IEC EN 61851-1:2017, IEC 61851-21-2:2018, EN 62196-1:2014, EN 62196-2:2016, CE |
Accredited Notification Body |
DEKRA |
Warranty |
Warranty |
2 years |
Downloads